Extinction (astronomy): Difference between revisions

From formulasearchengine
Jump to navigation Jump to search
en>Bibcode Bot
m Adding 1 arxiv eprint(s), 0 bibcode(s) and 0 doi(s). Did it miss something? Report bugs, errors, and suggestions at User talk:Bibcode Bot
 
en>Monkbot
Line 1: Line 1:
'''Micellar electrokinetic chromatography''' (MEKC), is a [[chromatography]] technique, used in [[analytical chemistry]]. It is a modification of [[capillary electrophoresis]] (CE), where the samples are separated by differential partitioning between [[micelles]] (pseudo-stationary phase) and a surrounding aqueous [[buffer solution]] (mobile phase).<ref>Terabe, S.; Otsuka, K.; Ichikawa, K.; Tsuchiya, A.; Ando, T. ''Anal. Chem''. '''1984''', ''56'', 111.</ref> 


The basic set-up and detection methods used for MEKC are the same as those used in CE.  The difference is that the solution contains a [[surfactant]] at a [[concentration]] that is greater than the [[critical micelle concentration]] (CMC).  Above this concentration, surfactant [[monomers]] are in [[chemical equilibrium|equilibrium]] with micelles.


Another day I woke up and realized - Now I have been solitary for a little while and following much intimidation from pals I now locate myself signed-up for online dating. They guaranteed me that there are a lot of sweet, ordinary and [http://Www.google.co.uk/search?hl=en&gl=us&tbm=nws&q=entertaining+people&gs_l=news entertaining people] to fulfill, so here goes the pitch!<br>My  [http://okkyunglee.com luke bryan show] friends and household are awesome and spending time with them at tavern gigs or meals is [http://Www.Answers.com/topic/constantly+critical constantly critical]. I have never been in to cabarets as I find that one can never get a significant conversation with the noise. I likewise have 2 undoubtedly cheeky and very cute dogs that are almost always excited to meet new individuals.<br>I strive to keep as physically healthy  [http://lukebryantickets.sgs-suparco.org who is luke bryan on tour with] as possible staying at the gymnasium several times weekly. I enjoy my athletics and try to play or view as many a potential. I shall regularly at Hawthorn matches being wintertime. Notice: I've observed the carnage of wrestling fits at stocktake sales, Supposing that you contemplated buying an activity I really do not mind.<br><br>my blog post :: [http://lukebryantickets.citizenswebcasting.com luke bryan t]
In most applications, MEKC is performed in open capillaries under [[alkaline]] conditions to generate a strong [[electro-osmosis|electroosmotic flow]].  [[Sodium dodecyl sulfate]] (SDS) is the most commonly used surfactant in MEKC applications.  The anionic character of the sulfate groups of SDS cause the surfactant and micelles to have [[electrophoresis|electrophoretic mobility]] that is counter to the direction of the strong [[electroosmotic flow]].  As a result, the surfactant monomers and micelles migrate quite slowly, though their net movement is still toward the [[cathode]].<ref>Baker, D.R. “Capillary Electrophoresis” John Wiley & Sons, Inc.: New York, '''1995'''.</ref> During a MEKC separation, [[analyte]]s distribute themselves between the [[hydrophobe|hydrophobic]] interior of the micelle and [[hydrophile|hydrophilic]] buffer solution as shown in ''figure 1''.
 
[[Image:MEKC.gif|frame|Figure 1: Depiction of the distribution of analytes (A) based on their hydrophobicity.]]
 
Analytes that are [[soluble|insoluble]] in the interior of micelles should migrate at the electroosmotic flow velocity, <math>u_o</math>, and be detected at the retention time of the buffer, <math>t_M</math>.  Analytes that solubilize completely within the micelles (analytes that are highly hydrophobic) should migrate at the micelle velocity, <math>u_c</math>, and [[elution|elute]] at the final elution time, <math>t_c</math>.<ref name="AC1984_113">Terabe, S.; Otsuka, K.; Ichikawa, K.; Tsuchiya, A.; Ando, T. ''Anal. Chem''. '''1984''', ''56'', 113.</ref>
 
== Theory ==
The micelle velocity is defined by:
 
<math>u_c= u_p+u_o</math>
 
where <math>u_p</math> is the electrophoretic velocity of a micelle.<ref name="AC1984_113"/>
 
The retention time of a given sample should depend on the capacity factor, <math>k^1</math>:
 
<math>k^1=\frac{n_c}{n_w}</math>
 
where <math>n_c</math>  is the total number of [[mole (unit)|moles]] of solute in the micelle and <math>n_w</math> is the total moles in the aqueous phase.<ref name="AC1984_113"/>  The retention time of a solute should then be within the range:
 
<math> t_M\le t_r\le t_c </math>
 
Charged analytes have a more complex interaction in the capillary because they exhibit electrophoretic mobility, engage in [[electrostatics|electrostatic]] interactions with the micelle, and participate in hydrophobic partitioning.<ref name="Cunico1998">Cunico,R.L.; Goodin, K.M.; Wehr,T. “Basic HPLC and CE of Biomolecules” Bay Bioanalytical Laboratory: Richmond, CA, '''1998'''.</ref>
 
The fraction of the sample in the aqueous phase, <math>R</math>, is given by:
 
<math> R= \frac{u_s-u_c}{u_o-u_c}</math>
 
where <math>u_s</math> is the migration velocity of the solute.<ref name="AC1984_113"/>  The value <math>R</math> can also be expressed in terms of the capacity factor:
 
<math> R=\frac{1}{1+k^1}</math>
 
Using the relationship between velocity, tube length from the injection end to the detector cell (<math>L</math>), and retention time, <math>u_{o}= L/t_M</math>, <math>u_{c}= L/t_{c}</math> and <math>u_s = L/t_r</math>, a relationship between the capacity factor and retention times can be formulated:<ref name="Cunico1998"/>
 
<math> k^1=\frac{t_r-t_M}{t_M(1-(t_r/t_c))}</math>
 
The extra term enclosed in parenthesis accounts for the partial mobility of the hydrophobic phase in MEKC.<ref name="Cunico1998"/>  This equation resembles an expression derived for <math>k^1</math> in conventional [[packed bed]] chromatography:
 
<math> k=\frac{t_r-t_M}{t_M}</math>
 
A rearrangement of the previous equation can be used to write an expression for the retention factor:<ref>Foley, J.P.  ''Anal. Chem''.  '''1990''', ''62'', 1302.</ref>
 
<math>t_r =\left ( \frac{1+k^1}{1+(t_M/t_c)k^1} \right )t_M</math>
 
From this equation it can be seen that all analytes that partition strongly into the micellar phase (where <math>k^1</math> is essentially ∞) migrate at the same time, <math>t_c</math>.  In conventional chromatography, separation of similar compounds can be improved by [[gradient]] elution. In MEKC, however, techniques must be used to extend the elution range to separate strongly retained analytes.<ref name="Cunico1998"/>
 
Elution ranges can be extended by several techniques including the use of [[organic compound|organic]] modifiers, [[cyclodextrin]]s, and mixed micelle systems.  Short-chain alcohols or [[acetonitrile]] can be used as organic modifiers that decrease <math>t_M</math> and <math>k^1</math> to improve the resolution of analytes that co-elute with the micellar phase.  These agents, however, may alter the level of the EOF. Cyclodextrins are cyclic [[polysaccharide]]s that form inclusion complexes that can cause competitive hydrophobic partitioning of the analyte.  Since analyte-cyclodextrin complexes are neutral, they will migrate toward the cathode at a higher velocity than that of the negatively charged micelles.  Mixed micelle systems, such as the one formed by combining SDS with the neutral surfactant Brij-35, can also be used to alter the selectivity of MEKC.<ref name="Cunico1998"/>
 
== History ==
 
In 1984, the Terabe group reported a technique that enabled [[capillary electrophoresis]] (CE) instrumentation to be used in the separation of neutral (as well as ionic) species.
 
==Applications of MEKC==
The simplicity and efficiency of MEKC have made it an attractive technique for a variety of applications.  Further improvements can be made to the selectivity of MEKC by adding [[chirality (chemistry)|chiral]] selectors or chiral surfactants to the system.  Unfortunately, this technique is not suitable for protein analysis because proteins are generally too large to partition into a surfactant micelle and tend to bind to surfactant [[monomer]]s to form SDS-protein complexes.<ref>Skoog, D.A.; Holler, F.J.; Nieman, T.A.  “Principles of Instrumental Analysis, 5th ed.” Saunders college Publishing: Philadelphia, '''1998'''.</ref> 
 
Recent applications of MEKC include the analysis of uncharged [[pesticide]]s,<ref>Carretero, A.S.; Cruces-Blanco, C.; Ramirez, S.C.; Pancorbo, A.C.; Gutierrez, A.F.  ''J. Agric. Food. Chem''. '''2004''', ''52'', 5791.</ref> essential and branched-chain [[amino acid]]s in nutraceutical products,<ref>Cavazza, A.; Corradini, C.; Lauria, A.; Nicoletti, I.  ''J. Agric. Food Chem''. '''2000''', ''48'', 3324.</ref> [[hydrocarbon]] and alcohol contents of the [[marjoram]] herb.<ref>Rodrigues, M.R.A.; Caramao, E.B.; Arce, L.; Rios, A.; Valcarcel, M.  ''J. Agric. Food Chem''. '''2002''', ''50'', 425.</ref> 
 
MEKC has also been targeted for its potential to be used in combinatorial chemical analysis.    The advent of [[combinatorial chemistry]] has enabled [[medicinal chemistry|medicinal chemists]] to synthesize and identify large numbers of potential [[medication|drugs]] in relatively short periods of time. Small sample and [[solvent]] requirements and the high resolving power of MEKC have enabled this technique to be used to quickly analyze a large number of compounds with good resolution.  
 
Traditional methods of analysis, like [[high-performance liquid chromatography]] (HPLC), can be used to identify the purity of a combinatorial library, but assays need to be rapid with good resolution for all components to provide useful information for the chemist.<ref>Simms, P.J.; Jeffries, C.T.; Huang, Y.; Zhang, L.; Arrhenius, T.; Nadzan, A.M.  ''J. Comb. Chem''.  '''2001''', ''3'', 427.</ref>   The introduction of surfactant to traditional capillary electrophoresis instrumentation has dramatically expanded the scope of analytes that can be separated by capillary electrophoresis.
 
== References ==
{{reflist}}
 
== Sources ==
* Kealey, D.;Haines P.J.; instant notes, Analytical Chemistry page 182-188
{{chromatography}}
 
[[Category:Chromatography]]

Revision as of 15:45, 18 January 2014

Micellar electrokinetic chromatography (MEKC), is a chromatography technique, used in analytical chemistry. It is a modification of capillary electrophoresis (CE), where the samples are separated by differential partitioning between micelles (pseudo-stationary phase) and a surrounding aqueous buffer solution (mobile phase).[1]

The basic set-up and detection methods used for MEKC are the same as those used in CE. The difference is that the solution contains a surfactant at a concentration that is greater than the critical micelle concentration (CMC). Above this concentration, surfactant monomers are in equilibrium with micelles.

In most applications, MEKC is performed in open capillaries under alkaline conditions to generate a strong electroosmotic flow. Sodium dodecyl sulfate (SDS) is the most commonly used surfactant in MEKC applications. The anionic character of the sulfate groups of SDS cause the surfactant and micelles to have electrophoretic mobility that is counter to the direction of the strong electroosmotic flow. As a result, the surfactant monomers and micelles migrate quite slowly, though their net movement is still toward the cathode.[2] During a MEKC separation, analytes distribute themselves between the hydrophobic interior of the micelle and hydrophilic buffer solution as shown in figure 1.

Figure 1: Depiction of the distribution of analytes (A) based on their hydrophobicity.

Analytes that are insoluble in the interior of micelles should migrate at the electroosmotic flow velocity, , and be detected at the retention time of the buffer, . Analytes that solubilize completely within the micelles (analytes that are highly hydrophobic) should migrate at the micelle velocity, , and elute at the final elution time, .[3]

Theory

The micelle velocity is defined by:

where is the electrophoretic velocity of a micelle.[3]

The retention time of a given sample should depend on the capacity factor, :

where is the total number of moles of solute in the micelle and is the total moles in the aqueous phase.[3] The retention time of a solute should then be within the range:

Charged analytes have a more complex interaction in the capillary because they exhibit electrophoretic mobility, engage in electrostatic interactions with the micelle, and participate in hydrophobic partitioning.[4]

The fraction of the sample in the aqueous phase, , is given by:

where is the migration velocity of the solute.[3] The value can also be expressed in terms of the capacity factor:

Using the relationship between velocity, tube length from the injection end to the detector cell (), and retention time, , and , a relationship between the capacity factor and retention times can be formulated:[4]

The extra term enclosed in parenthesis accounts for the partial mobility of the hydrophobic phase in MEKC.[4] This equation resembles an expression derived for in conventional packed bed chromatography:

A rearrangement of the previous equation can be used to write an expression for the retention factor:[5]

From this equation it can be seen that all analytes that partition strongly into the micellar phase (where is essentially ∞) migrate at the same time, . In conventional chromatography, separation of similar compounds can be improved by gradient elution. In MEKC, however, techniques must be used to extend the elution range to separate strongly retained analytes.[4]

Elution ranges can be extended by several techniques including the use of organic modifiers, cyclodextrins, and mixed micelle systems. Short-chain alcohols or acetonitrile can be used as organic modifiers that decrease and to improve the resolution of analytes that co-elute with the micellar phase. These agents, however, may alter the level of the EOF. Cyclodextrins are cyclic polysaccharides that form inclusion complexes that can cause competitive hydrophobic partitioning of the analyte. Since analyte-cyclodextrin complexes are neutral, they will migrate toward the cathode at a higher velocity than that of the negatively charged micelles. Mixed micelle systems, such as the one formed by combining SDS with the neutral surfactant Brij-35, can also be used to alter the selectivity of MEKC.[4]

History

In 1984, the Terabe group reported a technique that enabled capillary electrophoresis (CE) instrumentation to be used in the separation of neutral (as well as ionic) species.

Applications of MEKC

The simplicity and efficiency of MEKC have made it an attractive technique for a variety of applications. Further improvements can be made to the selectivity of MEKC by adding chiral selectors or chiral surfactants to the system. Unfortunately, this technique is not suitable for protein analysis because proteins are generally too large to partition into a surfactant micelle and tend to bind to surfactant monomers to form SDS-protein complexes.[6]

Recent applications of MEKC include the analysis of uncharged pesticides,[7] essential and branched-chain amino acids in nutraceutical products,[8] hydrocarbon and alcohol contents of the marjoram herb.[9]

MEKC has also been targeted for its potential to be used in combinatorial chemical analysis. The advent of combinatorial chemistry has enabled medicinal chemists to synthesize and identify large numbers of potential drugs in relatively short periods of time. Small sample and solvent requirements and the high resolving power of MEKC have enabled this technique to be used to quickly analyze a large number of compounds with good resolution.

Traditional methods of analysis, like high-performance liquid chromatography (HPLC), can be used to identify the purity of a combinatorial library, but assays need to be rapid with good resolution for all components to provide useful information for the chemist.[10] The introduction of surfactant to traditional capillary electrophoresis instrumentation has dramatically expanded the scope of analytes that can be separated by capillary electrophoresis.

References

43 year old Petroleum Engineer Harry from Deep River, usually spends time with hobbies and interests like renting movies, property developers in singapore new condominium and vehicle racing. Constantly enjoys going to destinations like Camino Real de Tierra Adentro.

Sources

  • Kealey, D.;Haines P.J.; instant notes, Analytical Chemistry page 182-188

Template:Chromatography

  1. Terabe, S.; Otsuka, K.; Ichikawa, K.; Tsuchiya, A.; Ando, T. Anal. Chem. 1984, 56, 111.
  2. Baker, D.R. “Capillary Electrophoresis” John Wiley & Sons, Inc.: New York, 1995.
  3. 3.0 3.1 3.2 3.3 Terabe, S.; Otsuka, K.; Ichikawa, K.; Tsuchiya, A.; Ando, T. Anal. Chem. 1984, 56, 113.
  4. 4.0 4.1 4.2 4.3 4.4 Cunico,R.L.; Goodin, K.M.; Wehr,T. “Basic HPLC and CE of Biomolecules” Bay Bioanalytical Laboratory: Richmond, CA, 1998.
  5. Foley, J.P. Anal. Chem. 1990, 62, 1302.
  6. Skoog, D.A.; Holler, F.J.; Nieman, T.A. “Principles of Instrumental Analysis, 5th ed.” Saunders college Publishing: Philadelphia, 1998.
  7. Carretero, A.S.; Cruces-Blanco, C.; Ramirez, S.C.; Pancorbo, A.C.; Gutierrez, A.F. J. Agric. Food. Chem. 2004, 52, 5791.
  8. Cavazza, A.; Corradini, C.; Lauria, A.; Nicoletti, I. J. Agric. Food Chem. 2000, 48, 3324.
  9. Rodrigues, M.R.A.; Caramao, E.B.; Arce, L.; Rios, A.; Valcarcel, M. J. Agric. Food Chem. 2002, 50, 425.
  10. Simms, P.J.; Jeffries, C.T.; Huang, Y.; Zhang, L.; Arrhenius, T.; Nadzan, A.M. J. Comb. Chem. 2001, 3, 427.