Winsorized mean: Difference between revisions

From formulasearchengine
Jump to navigation Jump to search
→‎Drawbacks: example should be its own section; clarify link
en>Cherkash
m caps
 
Line 1: Line 1:
[[Image:betz tube.jpg|right|thumb|280px|Schematic of fluid flow through a disk-shaped actuator. For a constant density fluid cross sectional area varies inversely with speed.]]
The writer's name is Christy Brookins. Ohio is where his house is and his family members enjoys it. To climb is some thing I really enjoy doing. He is an info officer.<br><br>Here is my weblog; accurate psychic predictions ([http://www.familysurvivalgroup.com/easy-methods-planting-looking-backyard/ click the next document])
 
'''Betz's law''' calculates the maximum power that can be extracted from the wind, independent of the design of a [[wind turbine]] in open flow. It was published in 1919, by the German physicist [[Albert Betz]].<ref>Betz, A. (1966) ''Introduction to the Theory of Flow Machines.'' (D. G. Randall, Trans.) Oxford: Pergamon Press.</ref> The law is derived from the principles of conservation of mass and momentum of the air stream flowing through an idealized "actuator disk" that extracts energy from the wind stream. According to Betz's law, no turbine can capture more than 16/27 (59.3%) of the [[kinetic energy]] in wind.  The factor 16/27 (0.593) is known as Betz's coefficient.  Practical utility-scale wind turbines achieve at peak 75% to 80% of the Betz limit.<ref name=Enercon/><ref>Tony Burton et al., (ed), ''Wind Energy Handbook'', John Wiley and Sons 2001 ISBN 0471489972 page 65</ref>
 
The Betz limit is based on an open disk actuator; if a [[diffuser]] is used to collect additional wind flow and direct it through the turbine, more energy can be extracted. However, such shrouded turbines are costly to build in utility-scale units because of the extra structure required.<ref>Burton et. al, ''Wind Energy Handbook'', chapter 5 ''Shrouded Turbines''</ref>
 
==Concepts==
[[File:100% Wind Turbine Efficiency.png|thumb|100% Wind Turbine Efficiency|Simple cartoon of two air molecules shows why wind turbines cannot actually run at 100% efficiency.]]
 
Betz' Law applies to all [[Newtonian fluids]], but this article will use wind as an example. Consider that if all of the energy coming from wind movement through a turbine was extracted as useful energy the wind speed afterwards would drop to zero. If the wind stopped moving at the exit of the turbine, then no more fresh wind could get in - it would be blocked. In order to keep the wind moving through the turbine there has to be some wind movement, however small, on the other side with a wind speed greater than zero.  Betz' law shows that as air flows through area, and when it slows from losing energy to extraction from a turbine, it must spread out to a wider area.  As a result geometry limits any turbine efficiency to 59.3%.
 
== Three independent discoveries of the turbine efficiency limit ==
 
The British scientist [[Frederick W. Lanchester]] derived the same maximum in 1915. The leader of the  Russian aerodynamic school, [[Nikolay Yegorovich Zhukovsky|Zhukowsky]], also published the same result for an ideal wind turbine in 1920, the same year as Betz did.<ref>Gijs A.M. van Kuik, [http://www.tudelft.nl/live/ServeBinary?id=5b6d6215-c7cd-4867-9712-e4c9d74ed533&binary=/doc/The%20Lancheste%20Betz%20Joukowsky%20limit%20WE10-3%20GvK.pdf ''The Lanchester–Betz–Joukowsky Limit''], Wind Energ. 2007; 10:289–291</ref>  It is thus an example of [[Stigler's Law]].
 
== Economic relevance ==
The Betz limit places an upper bound on the annual energy that can be extracted at a site. Even if a hypothetical wind blew consistently for a full year, no more than the Betz limit of the energy contained in that year's wind could be extracted. In practice, the annual capacity factor of a wind site varies around 25% to 60% of the energy that could be generated with constant wind.
 
Essentially increasing system economic efficiency results from increased production per unit (per windmill square meter of vane exposure or other system component, such as the transmission)  Increases in system efficiency which are marginal decreases in cost per kWh are required to bring down the cost of electrical power production. These efficiency increases may or may not be the result of engineering efficiencies that push into the higher levels of the Betz limit. System efficiency increases in power application, transmission or storage may do the same thing at lower cost/unit of power.
 
== Proof ==
 
It shows the maximum possible energy — known as the '''Betz limit''' — that may be derived by means of an infinitely thin rotor from a fluid flowing at a certain speed.
 
In order to calculate the maximum theoretical efficiency of a thin rotor (of, for example, a [[windmill]]) one imagines it to be replaced by a disc that withdraws energy from the fluid passing through it. At a certain distance behind this disc the fluid that has passed through flows with a reduced velocity.
 
=== Assumptions ===
 
1. The rotor does not possess a hub, this is an ideal rotor, with an infinite number of blades which have no drag.  Any resulting drag would only lower this idealized value.
 
2. The flow into and out of the rotor is axial.  This is a control volume analysis, and to construct a solution the control volume must contain all flow going in and out, failure to account for that flow would violate the conservation equations.
 
3. The flow is incompressible.  Density remains constant, and there is no heat transfer.
 
=== Application of conservation of mass (continuity equation) ===
 
Applying conservation of mass to this control volume, the [[mass flow rate]] (the mass of fluid flowing per unit time) is given by:
 
: <math> \dot m = \rho \cdot A_1 \cdot v_1 = \rho \cdot S \cdot v = \rho \cdot A_2 \cdot v_2 </math>
 
where ''v''<sub>1</sub> is the speed in the front of the rotor and ''v''<sub>2</sub> is the speed downstream of the rotor, and ''v'' is the speed at the fluid power device.  ''ρ'' is the fluid density, and the area of the turbine is given by ''S''.  The force exerted on the wind by the rotor may be written as
: <math> \begin{align} F
& = m \cdot a \\
& = m \cdot \tfrac {dv} {dt} \\
& = \dot m \cdot \Delta v \\
& = \rho \cdot S \cdot v \cdot \left ( v_1 - v_2 \right ) \\
\end{align} </math>
 
=== Power and work ===
 
The [[Power (physics)|work done]] by the force may be written incrementally as
 
: <math> dE = F \cdot dx </math>
 
and the power (rate of work done) of the wind is
 
: <math> P = \begin{matrix} \frac{dE}{dt} \end{matrix} = F \cdot \begin{matrix} \frac{dx}{dt} \end{matrix} = F \cdot v </math>
 
Now substituting the force ''F'' computed above into the power equation will yield the power extracted from the wind:
 
: <math> P = \rho \cdot S \cdot v^2 \cdot (v_1-v_2) </math>
 
However, power can be computed another way, by using the kinetic energy.  Applying the conservation of energy equation to the control volume yields
 
: <math> P = \begin{matrix} \frac{\Delta E}{\Delta t} \end{matrix} </math>
 
:: <math> = \begin{matrix} \frac12 \end{matrix} \cdot \dot m \cdot (v_1^2 - v_2^2) </math>
 
Looking back at the continuity equation, a substitution for the mass flow rate yields the following
 
: <math> P = \begin{matrix} \frac12 \end{matrix} \cdot \rho \cdot S \cdot v \cdot (v_1^2 - v_2^2) </math>
 
Both of these expressions for power are completely valid, one was derived by examining the incremental work done and the other by the conservation of energy.  Equating these two expressions yields
 
: <math> P = \begin{matrix} \frac12 \end{matrix} \cdot \rho \cdot S \cdot v \cdot (v_1^2 - v_2^2) = \rho \cdot S \cdot v^2 \cdot (v_1-v_2) </math>
 
Examining the two equated expressions yields an interesting result, mainly
 
: <math> \begin{matrix} \frac12 \end{matrix} \cdot (v_1^2-v_2^2) = \begin{matrix} \frac12 \end{matrix} \cdot (v_1 - v_2) \cdot (v_1 + v_2) = v \cdot (v_1-v_2) </math>
 
or
 
: <math> v = \begin{matrix} \frac12 \end{matrix} \cdot (v_1 + v_2) </math>
 
Therefore, the wind velocity at the rotor may be taken as the average of the upstream and downstream velocities.  (This is arguably the most counter-intuitive stage of the derivation of Betz' law.)
 
== Betz' law and coefficient of performance ==
 
Returning to the previous expression for [[Power (physics)|power]] based on kinetic energy:
 
: <math> \dot E = \begin{matrix} \frac12 \end{matrix} \cdot \dot m \cdot \left(v_1^2 - v_2^2\right) </math>
 
:: <math> = \begin{matrix} \frac12 \end{matrix} \cdot \rho \cdot S \cdot v \cdot \left(v_1^2 - v_2^2\right) </math>
 
:: <math> = \begin{matrix} \frac14 \end{matrix} \cdot \rho \cdot S \cdot \left(v_1 + v_2\right) \cdot \left(v_1^2 - v_2^2\right) </math>
 
:: <math> = \begin{matrix} \frac14 \end{matrix} \cdot \rho \cdot S \cdot v_1^3 \cdot \left(1 - \left(\frac{v_2}{v_1}\right)^2 + \left(\frac{v_2}{v_1}\right) - \left(\frac{v_2}{v_1}\right)^3\right) </math>.
 
[[Image:Ratio.gif|right|thumb|280px|The horizontal axis reflects the ratio ''v''<sub>2</sub>/''v''<sub>1</sub>, the vertical axis is the "power coefficient [http://www.talentfactory.dk/en/tour/wres/cp.htm]" ''C''<sub>p</sub>.]]
By [[Derivative|differentiating]]<math> \dot E </math> with respect to <math> \frac{v_2}{v_1} </math> for a given fluid speed ''v<sub>1</sub>'' and a given area ''S'' one finds the ''maximum'' or ''minimum'' value for <math> \dot E </math>. The result is that <math> \dot E </math> reaches maximum value when <math> \begin{matrix} \frac {v_2}{v_1} = \frac13 \end{matrix} </math>.
 
Substituting this value results in:
 
: <math> P_{\rm max} = \begin{matrix} \frac{16}{27} \cdot \frac{1}{2} \end{matrix} \cdot \rho \cdot S \cdot v_1^3 </math>.
 
The power obtainable from a cylinder of fluid with cross sectional area ''S'' and velocity ''v<sub>1</sub>'' is:
 
: <math> P = C_\mathrm{p} \cdot \begin{matrix} \frac12 \end{matrix} \cdot \rho \cdot S \cdot v_1^3  </math>.
 
The reference power for the betz efficiency calculation is the power in a moving fluid in a cylinder with cross sectional area ''S'' and velocity ''v<sub>1</sub>'':
 
: <math> P_{\rm wind}  = \begin{matrix} \frac12 \end{matrix} \cdot \rho \cdot S \cdot v_1^3 </math>.
 
The ''"power coefficient<ref>[http://www.talentfactory.dk/en/tour/wres/cp.htm "Danish Wind Industry Association"]</ref>"'' ''C''<sub>p</sub> (= ''P''/''P''<sub>wind</sub>) has a maximum value of: ''C''<sub>p.max</sub>&nbsp;= 16/27&nbsp;= 0.593 (or 59.3%; however, coefficients of performance are usually expressed as a decimal, not a percentage).
 
Modern large wind turbines achieve peak values for ''C''<sub>p</sub> in the range of 0.45 to 0.50,<ref name=Enercon>[http://www.enercon.de/p/downloads/EN_Productoverview_0710.pdf "Enercon E-family, 330 Kw to 7.5 Mw, Wind Turbine Specification"]</ref> about 75% to 85% of the theoretically possible maximum. In high wind speed where the turbine is operating at its rated power the turbine rotates (pitches) its blades to lower ''C''<sub>p</sub> to protect itself from damage. The power in the wind increases by a factor of 8 from 12.5 to 25&nbsp;m/s, so ''C''<sub>p</sub> must fall accordingly, getting as low as 0.06 for winds of 25&nbsp;m/s.
 
== Understanding the Betz results  ==
 
The Betz results are at first glance a little hard to understand. For example, why is the maximum Betz efficiency 59.3%, when a speed ratio of [V2/V1 = .333] implies the air passing through the rotor has lost 88.9% of its kinetic energy? The left side of the betz curve shows a maximum efficiency of 50% when the exiting air (V2) has no axial velocity. Is this realistic?
 
The answer to the second question is easy. 50% efficiency at [V2 = 0] is not realistic, the model breaks down at very low exit speeds. The Betz model assumes a constant density fluid and that implies the cross sectional area of the flow varies inversely with axial speed. At [V2 = 0] the cross sectional area is infinite! Mathematically the exiting air does not 'pile up' because it is spreading radially, but radial kinetic energies are not accounted for in the Betz model.
 
To show that 59.3% Betz efficiency is indeed consistent with a loss of 88.9% of kinetic energy in the air passing through the rotor a physical picture is helpful. The equations for power extracted from the air flow apply to the 'milk bottle' shaped flow shown in the figure at the beginning of this article. The upstream flow (V1) has a cross sectional area less than the rotor area (S). As the flow approaches the rotor, it begins to lose energy, and as it passes through the rotor the equations show it expands to exactly the rotor area (S).
 
The last step in calculating the Betz efficiency (''C''<sub>p</sub>) is to divide the calculated power extracted from the flow by a reference power value. The Betz analysis uses for its power reference, reasonably, the power of air upstream moving at V1 contained in a cylinder with the cross sectional area of the rotor (S).
 
The key to understanding why the Betz limit is lower than implied by the speed ratio is to understand that some of the air in the Betz reference cylinder does not pass through the rotor. The area of the flow that will pass through the rotor is upstream smaller than the rotor area. It expands to the rotor area as it reaches the rotor, implying that roughly half the energy transfer from the air to the rotor occurs before passage through the rotor. Thus it must be the case that the air just outside the flow gets pushed radially outward as the rotor is approached just enough so that it bypasses the rotor. The Betz equations do not include any terms for air that bypasses the rotor, its contribution to the extracted power is assumed to be zero.
 
As a check, let's calculate conditions at the Betz limit: 59.3% efficiency at [V2/V1 = .333]. The equations show the flow speed at the rotor is the (arithmetic) average of V1 and V2, or [V1 (1 + .333)/2 = .666 V1]. For constant density fluid the product of the speed and area are constant everywhere along the flow, so [V1 x A1 =.666 V1 x S], where A1 is the area of the flow upstream at V1. Thus A1/S = .666, meaning only 2/3 of the air in the upstream reference cylinder will eventually pass through the rotor and contribute to the extracted power. Thus the denominator in the Betz efficiency calculation is (in effect) inflated by 3/2, so the efficiency based on speed changes (88.9%) must be scaled by inverse of 3/2, or 2/3. [88.9% x .666 = 59.3%] gives us the Betz limit. Checks.
 
The Betz model can also be used to estimate the downstream air speed of real wind turbines. Kinetic energy of wind depends on speed squared, so if a modern large wind turbine is extracting half the wind's energy, which is possible, then from energy considerations it would seem that the downstream air speed (V2) should be x.707 of the upstream air speed (V1). But this is not what the Betz curve shows. Solving the Betz equation for [Cp = .50] yields [V2/V1 = .617] with 81% of the air in the upstream reference cylinder actually going through the blade circle, and 19% bypassing the blades due to a radial outward push from the inner expanding air flow as it approaches the blades.
 
== Points of interest ==
 
Note that the preceding analysis has no dependence on the geometry, therefore S may take any form provided that the flow travels axially from the entrance to the control volume to the exit, and the control volume has uniform entry and exit velocities.  Note that any extraneous effects can only decrease the performance of the turbine since this analysis was idealized to disregard friction.  Any non-ideal effects would detract from the energy available in the incoming fluid, lowering the overall efficiencies. 
 
There have been several arguments made about this limit and the effects of nozzles, and there is a distinct difficulty when considering power devices that use more captured area than the area of the rotor.  Some manufacturers and inventors have made claims of exceeding the Betz' limit by doing just this; in reality, their initial assumptions are wrong, since they are using a substantially larger <math>A_1</math> than the size of their rotor, and this skews their efficiency number.  In reality, the rotor is just as efficient as it would be without the nozzle or capture device, but by adding such a device you make more power available in the upstream wind from the rotor.
 
''Observation:  If we use the middle following (harmonic mean) of the speeds''
 
<math>V_{avg} = \frac{2}{\frac{1}{V_1} + \frac{1}{V_2}} = \frac{2 V_1 V_2}{V_1 + V_2}</math>
 
''To take the place of <math>V_{avg} = (V_1+V_2)/{2}</math>,
''
''then if <math>V_2=0</math> then <math>V_{avg}=0</math> for whatever value of <math>V_1</math> (impact without motion).
''
''The calculation is very simple and gives a 50% output.
''
 
== Modern development ==
 
In 1935 [[Hermann Glauert|H. Glauert]] derived the expression for turbine efficiency, when the angular component of velocity is taken into account, by applying an energy balance across the rotor plane.<ref>White, F.M., ''Fluid Mechanics'', 2nd Edition, 1988, McGraw-Hill, Singapore</ref> Due to the Glauert model, efficiency is below the Betz limit, and asymptotically approaches this limit when the tip speed ratio goes to infinity.
 
In 2001, Gorban, Gorlov and Silantyev introduced an exactly solvable model (GGS), that considers non-uniform pressure distribution and curvilinear flow across the turbine plane (issues not included in the Betz approach).<ref>Gorban' A.N., Gorlov A.M., Silantyev V.M., [http://www.math.le.ac.uk/people/ag153/homepage/Gorlov2001.pdf ''Limits of the Turbine Efficiency for Free Fluid Flow''], Journal of Energy Resources Technology - December 2001 - Volume 123, Issue 4, pp. 311-317.</ref> The GGS model predicts that peak efficiency is achieved when the flow through the turbine is approximately 61% which is very similar to the Betz result of 2/3, but the GGS predicted peak efficiency is much smaller: 30.1%.
 
Recently, viscous computations based on [[computational fluid dynamics]] (CFD) were applied to wind turbine modelling and demonstrated satisfactory agreement with experiment.<ref>Hartwanger, D., Horvat, A., [http://www.caspus.eclipse.co.uk/ah/publications/3dmwtucfd.pdf ''3D Modelling of A Wind Turbine Using CFD''], NAFEMS UK Conference 2008 "Engineering Simulation: Effective Use and Best Practice", Cheltenham, UK, June 10–11, 2008, Proceedings.</ref> Computed optimal efficiency is, typically, between the Betz limit and the GGS solution.
 
== See also ==
{{Portal box|Physics|Renewable energy}}
* [[Newtonian fluids]]
* [[Computational fluid dynamics|computational fluid dynamics (CFD)]]
* [[wind turbine]]
 
== References ==
{{refbegin}}
<references/>
* Ahmed, N.A. & Miyatake, M. ''A Stand-Alone Hybrid Generation System Combining Solar Photovoltaic and Wind Turbine with Simple Maximum Power Point Tracking Control,'' IEEE Power Electronics and Motion Control Conference, 2006. IPEMC '06. CES/IEEE 5th International, Volume 1,  Aug. 2006 pages 1–7.
 
{{refend}}
 
{{Wind power}}
 
{{DEFAULTSORT:Betz' Law}}
[[Category:Wind power]]

Latest revision as of 01:44, 5 September 2014

The writer's name is Christy Brookins. Ohio is where his house is and his family members enjoys it. To climb is some thing I really enjoy doing. He is an info officer.

Here is my weblog; accurate psychic predictions (click the next document)