I'm a 41 years old and study at the high school (Chemistry).<br>In my free time I try to learn Arabic. I've been twicethere and look forward to returning anytime soon. I love to read, preferably on my ipad. I like to watch Doctor Who and Modern Family as well as documentaries about nature. I love Machining.<br><br>Check out my site [http://www.amazon.com/Classic-Silver-Plated-Crystal-Bracelet/dp/B00KHA2TRA las vegas bracelet]
{{about|the meteorological dew point|the petroleum term|Hydrocarbon dew point}}
 
The '''dew point''' is the [[temperature]] at which the [[water vapor]] in [[air]] at constant [[barometric pressure]] [[Condensation|condense]]s into liquid water at the same rate at which it evaporates. At temperatures below the dew point, water will leave the air.  The condensed water is called [[dew]] when it forms on a solid surface.
 
The dew point is a water-to-air saturation temperature. The dew point is associated with relative [[humidity]]. A high [[relative humidity]] indicates that the dew point is closer to the current air temperature. Relative humidity of 100% indicates the dew point is equal to the current temperature and that the air is maximally saturated with water. When the moisture content remains constant and temperature increases, relative humidity decreases.<ref name=Horstmeyer>{{Cite web| last=Horstmeyer | first=Steve | title=Relative Humidity....Relative to What? The Dew Point Temperature...a better approach | publisher=Steve Horstmeyer, Meteorologist, WKRC TV, Cincinnati, Ohio, USA | date=2006-08-15 | url=http://www.shorstmeyer.com/wxfaqs/humidity/humidity.html| accessdate=2009-08-20}}</ref>
 
[[General aviation]] pilots use dew-point data to calculate the likelihood of [[carburetor icing]] and [[fog]], and to estimate the height of the [[cloud base]].
 
[[Image:dewpoint.jpg|300px|right|thumb|This graph shows the maximum percentage, by mass, of water vapor that air at sea-level across a range of temperatures can contain.]]
 
At a given temperature but ''independent'' of [[barometric pressure]], the dew point is a consequence of the [[Humidity#Absolute humidity|absolute humidity]], the mass of water per unit volume of air. If both the temperature and pressure rise, however, the dew point will increase and the relative humidity will decrease accordingly. Reducing the absolute humidity without changing other variables will bring the dew point back down to its initial value. In the same way, increasing the absolute humidity after a temperature drop brings the dew point back down to its initial level.  If the temperature rises in conditions of constant pressure, then the dew point will remain constant but the relative humidity will drop.
For this reason, a constant relative humidity (%) with different temperatures implies that when it's hotter, a higher fraction of the air is water vapor than when it's cooler.
 
At a given barometric pressure but ''independent'' of temperature, the dew point indicates the [[mole fraction]] of water vapor in the air, or, put differently, determines the [[specific humidity]] of the air. If the pressure rises without changing this mole fraction, the dew point will rise accordingly; Reducing the mole fraction, i.e., making the air less humid, would bring the dew point back down to its initial value. In the same way, increasing the mole fraction after a pressure drop brings the relative humidity back up to its initial level.
Considering New York (33&nbsp;ft elevation) and Denver (5,280&nbsp;ft elevation),<ref name="denfacts">{{cite web|url = http://www.denvergov.org/AboutDenver/today_factsguide.asp|title = Denver Facts Guide&nbsp;– Today|publisher = The City and County of Denver|accessdate =March 19, 2007}}</ref> for example, this means that if the dew point and temperature in both cities are the same, then the mass of water vapor per cubic meter of air will be the same, but the mole fraction of water vapor in the air will be greater in Denver.
 
==Relationship to human comfort==
When the air temperature is high, the body's ''[[thermoregulation]]'' uses evaporation of [[perspiration]] to cool down, with the cooling effect directly related to how fast the perspiration evaporates. The rate at which perspiration can evaporate depends on how much [[humidity|moisture]] is in the air and how much moisture the air can hold.  If the air is already saturated with moisture, perspiration will not evaporate.  The body's cooling system will produce perspiration in an effort to keep the body at its normal temperature even when the rate it is producing sweat exceeds the evaporation rate. So even without generating additional body heat by exercising, one can become coated with sweat on humid days. It is the unevaporated sweat that tends to make one feel uncomfortable in humid weather.
 
As the air surrounding one's body is warmed by body heat, it will rise and be replaced with other air.  If air is moved away from one's body with a natural breeze or a fan, sweat will evaporate faster, making perspiration more effective at cooling the body. The more unevaporated perspiration, the greater the discomfort.
 
A [[wet bulb thermometer]] also uses [[evaporative cooling]], so it provides a good analog for use in evaluating comfort level.
 
Discomfort also exists when the dew point is low (below around {{convert|-30|°C|°F|abbr=on}}). The drier air can cause skin to crack and become irritated more easily.  It will also dry out the respiratory paths. [[Occupational Safety and Health Administration|OSHA]] recommends indoor air be maintained at {{convert|20|to|24.5|C|F}} with a 20-60% relative humidity (a dew point of {{convert|-4.5|to|15.5|C|F}}).<ref>http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=24602</ref>
 
Lower dew points, less than {{convert|10|°C|°F|abbr=on}}, correlate with lower ambient temperatures and the body requires less cooling. A lower dew point can go along with a high temperature only at extremely low relative humidity (see graph below), allowing for relatively effective cooling.
 
Those accustomed to [[continental climate]]s often begin to feel uncomfortable when the dew point reaches between {{convert|15|and|20|C|F}}. Most inhabitants of these areas will consider dew points above {{convert|21|°C|°F|abbr=on}} oppressive.
 
{| class="wikitable" style="text-align:center;"
|-
! colspan="2"|Dew point
! Human perception<ref name=Horstmeyer/>
! Relative humidity at {{convert|32|°C|°F|abbr=on}}
|-
| Over 26 °C
| Over 80 °F
| Severely high. Even deadly for [[asthma]] related illnesses
| 65% and higher
|-
| 24–26 °C
| 75–80 °F
| Extremely uncomfortable, fairly oppressive
| 62%
|-
| 21–24 °C
| 70–74 °F
| Very humid, quite uncomfortable
| 52–60%
|-
| 18–21 °C
| 65–69 °F
| Somewhat uncomfortable for most people at upper edge
| 44–52%
|-
| 16–18 °C
| 60–64 °F
| OK for most, but all perceive the humidity at upper edge
| 37–46%
|-
| 13–16 °C
| 55–59 °F
| Comfortable
| 38–41%
|-
| 10–12 °C
| 50–54 °F
| Very comfortable
| 31–37%
|-
| Under 10 °C
| Under 50 °F
| A bit dry for some
| 30%
|}
 
==Measurement==
Devices called dew point meters are used to measure dew point over a wide range of temperatures. These devices consist of a polished metal mirror which is cooled as air is passed over it.  The temperature at which dew forms is, by definition, the dew point. Manual devices of this sort can be used to calibrate other types of humidity sensors, and automatic sensors may be used in a control loop with a humidifier or dehumidifier to control the dew point of the air in a building or in a smaller space for a manufacturing process.
 
==Calculating the dew point==
{{See also|Psychrometric chart}}
 
[[Image:Dewpoint-RH.svg|thum |center|Graph of the dependence of the dew point upon air temperature for several levels of relative humidity.]]
 
A well-known approximation used to calculate the dew point, ''T<sub>dp</sub>'', given just the actual ("dry bulb") air temperature, ''T'' and [[relative humidity]] (in percent), ''RH'', is the ''Magnus formula'':
:::<math>\begin{align}
\gamma(T,R\!H)&=\ln\left(\frac{R\!H}{100}\exp\left(\frac{bT}{c+T}\right)\right)=\ln\left(\frac{R\!H}{100}\right)+\frac{bT}{c+T};\\
T_{dp}&= \frac{c\gamma(T,R\!H)}{b-\gamma(T,R\!H)};\end{align}
</math>
The more complete formulation and origin of this approximation involves the interrelated [[Saturation (chemistry)|saturated]] water vapor pressure (in units of [[bar (unit)|millibar]], which is also [[Pascal (unit)|hPa]]) at ''T'', ''P<sub>s</sub>''(''T''), and the actual water vapor pressure (also in units of millibar), ''P<sub>a</sub>''(''T''), which can be either found with ''RH'' or approximated with the barometric pressure (in millibar units), ''BP<sub>mb</sub>'', and "[[wet-bulb temperature|wet-bulb]]" temperature, ''T<sub>w</sub>'' is:
 
:::<small>Note: unless declared otherwise, all temperatures are expressed and worked in degrees Celsius</small>
::::<math>
\begin{align}
P_s(T)& = \frac{100}{R\!H}P_\text{a}(T) = a\exp\left(\frac{bT}{c+T}\right);\\[8pt]
P_\text{a}(T) & = \frac{R\!H}{100}P_s(T)=a\exp(\gamma(T,R\!H)),\\
&\approx P_s(T_\text{w}) - B\!P_\text{mb} 0.00066 \left[1 + (0.00115T_\text{w} \right)]\left(T-T_\text{w}\right);\\[5pt]
T_\text{dp} & = \frac{c\ln(P_\text{a}(T)/a)}{b-\ln(P_\text{a}(T)/a)};\end{align}</math>
 
For greater accuracy, ''P<sub>s</sub>''(''T'') (and, therefore, γ(''T'',''RH'')) can be enhanced, using part of the ''Bögel modification'', also known as the [[Arden Buck equation]], which adds a fourth, ''d'' constant:
:::<math>\begin{align}P_{s:m}(T)&=a\exp\bigg(\left(b-\frac{T}{d}\right)\left(\frac{T}{c+T}\right)\bigg);\\[8pt]
\gamma_m(T,R\!H)&=\ln\Bigg(\frac{R\!H}{100}\exp
\bigg(\left(b-\frac{T}{d}\right)\left(\frac{T}{c+T}\right)\bigg)
\Bigg);\\
T_{dp}&= \frac{c\gamma_m(T,R\!H)}{b-\gamma_m(T,R\!H)};\end{align}</math>
:::''(where <math>\scriptstyle{a=6.1121\ \mathrm{millibar};\quad\;b= 18.678;\quad\;c= 257.14^\circ \mathrm{C};\quad\;d=234.5^\circ \mathrm{C}.}</math>)''
 
There are several different  constant sets in use. The ones used in [[NOAA]]'s presentation <ref>http://www.srh.noaa.gov/images/epz/wxcalc/rhTdFromWetBulb.pdf ''Relative Humidity and Dewpoint Temperature from Temperature and Wet-Bulb Temperature''</ref> are taken from a 1980 paper by David Bolton in the ''Monthly Weather Review'':<ref>[https://www.rsmas.miami.edu/users/pzuidema/Bolton.pdf "''The computation of equivalent potential temperature''", Monthly Weather Review], vol.108, pg.1047, Eq.10</ref>
:<math>\begin{align}a&=6.112\ \mathrm{millibar};\quad\;b&= 17.67;\quad\;c&= 243.5^\circ \mathrm{C};\end{align}</math>
These valuations provide a minimum accuracy of 0.1%, for
:::::-30°C ≤ ''T'' ≤ +35°C;
::::::1% < ''RH'' < 100%;
Also noteworthy is the Sonntag1990,<ref>[http://irtfweb.ifa.hawaii.edu/~tcs3/tcs3/Misc/Dewpoint_Calculation_Humidity_Sensor_E.pdf SHTxx Application Note Dew-point Calculation]</ref>
:<math>\scriptstyle{a=6.112\ \mathrm{millibar};\quad\;b= 17.62;\quad\;c= 243.12^\circ \mathrm{C}:\quad -45^\circ \mathrm{C}\le T\le +60^\circ \mathrm{C}\quad (<-0.35^\circ \mathrm{C})}</math>
Another common set of values originates from the 1974 ''Psychrometry and Psychrometric Charts'', as presented by '''''Paroscientific''''',<ref>[http://www.paroscientific.com/dewpoint.htm MET4 AND MET4A CALCULATION OF DEW POINT]</ref>
:<math>\scriptstyle{a=6.105\ \mathrm{millibar};\quad\;b= 17.27;\quad\;c= 237.7^\circ \mathrm{C}:\quad 0^\circ \mathrm{C}\le T\le +60^\circ \mathrm{C}\quad (\pm0.4^\circ \mathrm{C})}</math>
Also, in the ''Journal of Applied Meteorology and Climatology'',<ref>Buck, A. L. (1981), [http://www.public.iastate.edu/~bkh/teaching/505/arden_buck_sat.pdf "New equations for computing vapor pressure and enhancement factor"], J. Appl. Meteorol. 20: 1527–1532</ref> Arden Buck presents several different valuation sets, with different minimum accuracies for different temperature ranges.  Two particular sets provide a range of -40°C → +50°C between the two, with even greater minimum accuracy than all of the other, above sets (maximum error at given |C°| extreme):
:<math>\scriptstyle{a=6.1121\ \mathrm{millibar};\quad\;b= 17.368;\quad\;c= 238.88^\circ \mathrm{C}:\quad\quad\! 0^\circ \mathrm{C}\le T\le +50^\circ \mathrm{C}\;\;(\le0.05%)}</math>
:<math>\scriptstyle{a=6.1121\ \mathrm{millibar};\quad\;b= 17.966;\quad\;c= 247.15^\circ \mathrm{C}:\quad -40^\circ \mathrm{C}\le T\le 0^\circ \mathrm{C}\quad\! \;\;(\le0.06%)}</math>
 
===Simple approximation===
There is also a very simple approximation that allows conversion between the dew point, temperature and relative humidity.  This approach is accurate to within about ±1°C as long as the relative humidity is above 50%:
:<math>T_{dp}\approx T-\frac{100-R\!H}{5};</math>
and
:<math>R\!H\approx 100-5(T-T_{dp});\,</math>
 
This can be expressed as a simple rule of thumb:
<blockquote>
''For every 1°C difference in the dew point and dry bulb temperatures, the relative humidity decreases by 5%, starting with RH&nbsp;=&nbsp;100% when the dew point equals the dry bulb temperature.''
</blockquote>
 
The derivation of this approach, a discussion of its accuracy, comparisons to other approximations, and more information on the history and applications of the dew point are given in the Bulletin of the American Meteorological Society.<ref>M. G. Lawrence, "The relationship between relative humidity and the dew point temperature in moist air: A simple conversion and applications", Bull. Am. Meteorol. Soc., 86, 225&ndash;233, 2005</ref>
 
For temperatures in degrees Fahrenheit, these approximations work out to
:<math> T_{dp:f}\approx T_{f}-\frac{9}{25}(100-R\!H);</math>
and
:<math> R\!H\approx 100-\frac{25}{9}(T_{f}-T_{dp:f});</math>
 
For example, a relative humidity of 100% means dew point is the same as air temp. For 90% RH,  dew point is 3 degrees Fahrenheit lower than air temp. For every 10 percent lower, dew point drops 3&nbsp;°F.
 
== Frost point ==
 
The '''frost point''' is similar to the dew point, in that it is the temperature to which a given parcel of humid air must be cooled, at constant barometric pressure, for water vapor to be [[Deposition (phase transition)|deposited]] on a surface as ice without going through the liquid phase. (Compare with [[Sublimation (phase transition)|sublimation]].) The frost point for a given parcel of air is always higher than the dew point, as the stronger bonding between water molecules on the surface of ice requires higher temperature to break.<ref>{{cite web | url=http://www.theweatherprediction.com/habyhints/347/ | title=Frost point and dew point | accessdate=September 30, 2011 | author=Haby, Jeff}}</ref>
 
== See also ==
* [[Bubble point]]
* [[Carburetor heat]]
* [[Hydrocarbon dew point]]
* [[Psychrometrics]]
* [[Thermodynamic diagrams]]
 
==References==
{{Reflist|}}
 
==External links==
* [http://weather.gov/glossary/index.php?word=dew+point Dew point definition] NOAA Glossary
* [http://www.faqs.org/faqs/meteorology/temp-dewpoint/ Often Needed Answers about Temp, Humidity & Dew Point] from the sci.geo.meteorology
 
{{Meteorological variables}}
 
{{DEFAULTSORT:Dew Point}}
[[Category:Atmospheric thermodynamics]]
[[Category:Psychrometrics]]
[[Category:Threshold temperatures]]
 
[[sv:Luftfuktighet#Daggpunkt]]

Revision as of 04:31, 22 January 2014

29 yr old Orthopaedic Surgeon Grippo from Saint-Paul, spends time with interests including model railways, top property developers in singapore developers in singapore and dolls. Finished a cruise ship experience that included passing by Runic Stones and Church.

The dew point is the temperature at which the water vapor in air at constant barometric pressure condenses into liquid water at the same rate at which it evaporates. At temperatures below the dew point, water will leave the air. The condensed water is called dew when it forms on a solid surface.

The dew point is a water-to-air saturation temperature. The dew point is associated with relative humidity. A high relative humidity indicates that the dew point is closer to the current air temperature. Relative humidity of 100% indicates the dew point is equal to the current temperature and that the air is maximally saturated with water. When the moisture content remains constant and temperature increases, relative humidity decreases.[1]

General aviation pilots use dew-point data to calculate the likelihood of carburetor icing and fog, and to estimate the height of the cloud base.

This graph shows the maximum percentage, by mass, of water vapor that air at sea-level across a range of temperatures can contain.

At a given temperature but independent of barometric pressure, the dew point is a consequence of the absolute humidity, the mass of water per unit volume of air. If both the temperature and pressure rise, however, the dew point will increase and the relative humidity will decrease accordingly. Reducing the absolute humidity without changing other variables will bring the dew point back down to its initial value. In the same way, increasing the absolute humidity after a temperature drop brings the dew point back down to its initial level. If the temperature rises in conditions of constant pressure, then the dew point will remain constant but the relative humidity will drop. For this reason, a constant relative humidity (%) with different temperatures implies that when it's hotter, a higher fraction of the air is water vapor than when it's cooler.

At a given barometric pressure but independent of temperature, the dew point indicates the mole fraction of water vapor in the air, or, put differently, determines the specific humidity of the air. If the pressure rises without changing this mole fraction, the dew point will rise accordingly; Reducing the mole fraction, i.e., making the air less humid, would bring the dew point back down to its initial value. In the same way, increasing the mole fraction after a pressure drop brings the relative humidity back up to its initial level. Considering New York (33 ft elevation) and Denver (5,280 ft elevation),[2] for example, this means that if the dew point and temperature in both cities are the same, then the mass of water vapor per cubic meter of air will be the same, but the mole fraction of water vapor in the air will be greater in Denver.

Relationship to human comfort

When the air temperature is high, the body's thermoregulation uses evaporation of perspiration to cool down, with the cooling effect directly related to how fast the perspiration evaporates. The rate at which perspiration can evaporate depends on how much moisture is in the air and how much moisture the air can hold. If the air is already saturated with moisture, perspiration will not evaporate. The body's cooling system will produce perspiration in an effort to keep the body at its normal temperature even when the rate it is producing sweat exceeds the evaporation rate. So even without generating additional body heat by exercising, one can become coated with sweat on humid days. It is the unevaporated sweat that tends to make one feel uncomfortable in humid weather.

As the air surrounding one's body is warmed by body heat, it will rise and be replaced with other air. If air is moved away from one's body with a natural breeze or a fan, sweat will evaporate faster, making perspiration more effective at cooling the body. The more unevaporated perspiration, the greater the discomfort.

A wet bulb thermometer also uses evaporative cooling, so it provides a good analog for use in evaluating comfort level.

Discomfort also exists when the dew point is low (below around Template:Convert). The drier air can cause skin to crack and become irritated more easily. It will also dry out the respiratory paths. OSHA recommends indoor air be maintained at Template:Convert with a 20-60% relative humidity (a dew point of Template:Convert).[3]

Lower dew points, less than Template:Convert, correlate with lower ambient temperatures and the body requires less cooling. A lower dew point can go along with a high temperature only at extremely low relative humidity (see graph below), allowing for relatively effective cooling.

Those accustomed to continental climates often begin to feel uncomfortable when the dew point reaches between Template:Convert. Most inhabitants of these areas will consider dew points above Template:Convert oppressive.

Dew point Human perception[1] Relative humidity at Template:Convert
Over 26 °C Over 80 °F Severely high. Even deadly for asthma related illnesses 65% and higher
24–26 °C 75–80 °F Extremely uncomfortable, fairly oppressive 62%
21–24 °C 70–74 °F Very humid, quite uncomfortable 52–60%
18–21 °C 65–69 °F Somewhat uncomfortable for most people at upper edge 44–52%
16–18 °C 60–64 °F OK for most, but all perceive the humidity at upper edge 37–46%
13–16 °C 55–59 °F Comfortable 38–41%
10–12 °C 50–54 °F Very comfortable 31–37%
Under 10 °C Under 50 °F A bit dry for some 30%

Measurement

Devices called dew point meters are used to measure dew point over a wide range of temperatures. These devices consist of a polished metal mirror which is cooled as air is passed over it. The temperature at which dew forms is, by definition, the dew point. Manual devices of this sort can be used to calibrate other types of humidity sensors, and automatic sensors may be used in a control loop with a humidifier or dehumidifier to control the dew point of the air in a building or in a smaller space for a manufacturing process.

Calculating the dew point

DTZ's public sale group in Singapore auctions all forms of residential, workplace and retail properties, outlets, homes, lodges, boarding homes, industrial buildings and development websites. Auctions are at present held as soon as a month.

We will not only get you a property at a rock-backside price but also in an space that you've got longed for. You simply must chill out back after giving us the accountability. We will assure you 100% satisfaction. Since we now have been working in the Singapore actual property market for a very long time, we know the place you may get the best property at the right price. You will also be extremely benefited by choosing us, as we may even let you know about the precise time to invest in the Singapore actual property market.

The Hexacube is offering new ec launch singapore business property for sale Singapore investors want to contemplate. Residents of the realm will likely appreciate that they'll customize the business area that they wish to purchase as properly. This venture represents one of the crucial expansive buildings offered in Singapore up to now. Many investors will possible want to try how they will customise the property that they do determine to buy by means of here. This location has offered folks the prospect that they should understand extra about how this course of can work as well.

Singapore has been beckoning to traders ever since the value of properties in Singapore started sky rocketing just a few years again. Many businesses have their places of work in Singapore and prefer to own their own workplace area within the country once they decide to have a everlasting office. Rentals in Singapore in the corporate sector can make sense for some time until a business has discovered a agency footing. Finding Commercial Property Singapore takes a variety of time and effort but might be very rewarding in the long term.

is changing into a rising pattern among Singaporeans as the standard of living is increasing over time and more Singaporeans have abundance of capital to invest on properties. Investing in the personal properties in Singapore I would like to applaud you for arising with such a book which covers the secrets and techniques and tips of among the profitable Singapore property buyers. I believe many novice investors will profit quite a bit from studying and making use of some of the tips shared by the gurus." – Woo Chee Hoe Special bonus for consumers of Secrets of Singapore Property Gurus Actually, I can't consider one other resource on the market that teaches you all the points above about Singapore property at such a low value. Can you? Condominium For Sale (D09) – Yong An Park For Lease

In 12 months 2013, c ommercial retails, shoebox residences and mass market properties continued to be the celebrities of the property market. Models are snapped up in report time and at document breaking prices. Builders are having fun with overwhelming demand and patrons need more. We feel that these segments of the property market are booming is a repercussion of the property cooling measures no.6 and no. 7. With additional buyer's stamp responsibility imposed on residential properties, buyers change their focus to commercial and industrial properties. I imagine every property purchasers need their property funding to understand in value.

Graph of the dependence of the dew point upon air temperature for several levels of relative humidity.
Graph of the dependence of the dew point upon air temperature for several levels of relative humidity.

A well-known approximation used to calculate the dew point, Tdp, given just the actual ("dry bulb") air temperature, T and relative humidity (in percent), RH, is the Magnus formula:

The more complete formulation and origin of this approximation involves the interrelated saturated water vapor pressure (in units of millibar, which is also hPa) at T, Ps(T), and the actual water vapor pressure (also in units of millibar), Pa(T), which can be either found with RH or approximated with the barometric pressure (in millibar units), BPmb, and "wet-bulb" temperature, Tw is:

Note: unless declared otherwise, all temperatures are expressed and worked in degrees Celsius

For greater accuracy, Ps(T) (and, therefore, γ(T,RH)) can be enhanced, using part of the Bögel modification, also known as the Arden Buck equation, which adds a fourth, d constant:

(where )

There are several different constant sets in use. The ones used in NOAA's presentation [4] are taken from a 1980 paper by David Bolton in the Monthly Weather Review:[5]

These valuations provide a minimum accuracy of 0.1%, for

-30°C ≤ T ≤ +35°C;
1% < RH < 100%;

Also noteworthy is the Sonntag1990,[6]

Another common set of values originates from the 1974 Psychrometry and Psychrometric Charts, as presented by Paroscientific,[7]

Also, in the Journal of Applied Meteorology and Climatology,[8] Arden Buck presents several different valuation sets, with different minimum accuracies for different temperature ranges. Two particular sets provide a range of -40°C → +50°C between the two, with even greater minimum accuracy than all of the other, above sets (maximum error at given |C°| extreme):

Simple approximation

There is also a very simple approximation that allows conversion between the dew point, temperature and relative humidity. This approach is accurate to within about ±1°C as long as the relative humidity is above 50%:

and

This can be expressed as a simple rule of thumb:

For every 1°C difference in the dew point and dry bulb temperatures, the relative humidity decreases by 5%, starting with RH = 100% when the dew point equals the dry bulb temperature.

The derivation of this approach, a discussion of its accuracy, comparisons to other approximations, and more information on the history and applications of the dew point are given in the Bulletin of the American Meteorological Society.[9]

For temperatures in degrees Fahrenheit, these approximations work out to

and

For example, a relative humidity of 100% means dew point is the same as air temp. For 90% RH, dew point is 3 degrees Fahrenheit lower than air temp. For every 10 percent lower, dew point drops 3 °F.

Frost point

The frost point is similar to the dew point, in that it is the temperature to which a given parcel of humid air must be cooled, at constant barometric pressure, for water vapor to be deposited on a surface as ice without going through the liquid phase. (Compare with sublimation.) The frost point for a given parcel of air is always higher than the dew point, as the stronger bonding between water molecules on the surface of ice requires higher temperature to break.[10]

See also

References

43 year old Petroleum Engineer Harry from Deep River, usually spends time with hobbies and interests like renting movies, property developers in singapore new condominium and vehicle racing. Constantly enjoys going to destinations like Camino Real de Tierra Adentro.

External links

Template:Meteorological variables

sv:Luftfuktighet#Daggpunkt

  1. 1.0 1.1 Template:Cite web
  2. Template:Cite web
  3. http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=24602
  4. http://www.srh.noaa.gov/images/epz/wxcalc/rhTdFromWetBulb.pdf Relative Humidity and Dewpoint Temperature from Temperature and Wet-Bulb Temperature
  5. "The computation of equivalent potential temperature", Monthly Weather Review, vol.108, pg.1047, Eq.10
  6. SHTxx Application Note Dew-point Calculation
  7. MET4 AND MET4A CALCULATION OF DEW POINT
  8. Buck, A. L. (1981), "New equations for computing vapor pressure and enhancement factor", J. Appl. Meteorol. 20: 1527–1532
  9. M. G. Lawrence, "The relationship between relative humidity and the dew point temperature in moist air: A simple conversion and applications", Bull. Am. Meteorol. Soc., 86, 225–233, 2005
  10. Template:Cite web