In [[heat transfer]], '''conduction''' (or '''heat conduction''') is the transfer of [[heat]] energy by microscopic [[diffusion]] and collisions of particles or quasi-particles within a body due to a [[temperature gradient]]. The microscopically diffusing and colliding objects include molecules, electrons, atoms, and [[phonon]]s. They transfer microscopically disorganized kinetic and potential energy, which are jointly known as internal energy. Conduction can only take place within an object or material, or between two objects that are in direct or indirect contact with each other. Conduction takes place in all forms of [[ponderable matter]], such as solids, liquids, gases and plasmas.
My name is Ashly Yamamoto. I life in Hamburg Hausbruch (Germany).<br><br>Also visit my page; Fifa 15 Coin Generator [[http://blog.infidels.co.za/2010/09/kevin-fitzgerald-woolworths-lingerie.html blog.infidels.co.za]]
 
Whether by conduction or by thermal radiation, heat spontaneously flows from a body at a higher temperature to a body at a lower temperature.  In the absence of external drivers, temperature differences decay over time, and the bodies approach [[thermal equilibrium]].
 
In conduction, heat flows within and through the body itself. In contrast, in heat transfer by [[thermal radiation]], the transfer is often between bodies. Also possible is transfer of heat by a combination of conduction and thermal radiation. In convection, internal energy is carried between bodies by a material carrier. In solids, conduction is mediated by the combination of vibrations and collisions of molecules, of propagation and collisions of [[phonons]], and of diffusion and collisions of [[Free electron model|free electrons]]. In gases and liquids, conduction is due to the collisions and [[Molecular diffusion|diffusion]] of molecules during their random motion. [[Photons]] in this context do not collide with one another, and so heat transport by [[electromagnetic radiation]] is conceptually distinct from heat conduction by microscopic diffusion and collisions of material particles and phonons. In condensed matter, such as a solid or liquid, the distinction between conduction and radiative transfer of heat is clear in physical concept, but it is often not phenomenologically clear, unless the material is semi-transparent. In a gas the distinction is both conceptually and phenomenologically clear.
 
In the engineering sciences, heat transfer includes the processes of [[thermal radiation]], [[convection]], and sometimes mass transfer. Usually more than one of these processes occurs in a given situation. The conventional symbol for the material property, [[thermal conductivity]], is <math>k</math>.
 
==Overview==
{{See also|heat equation}}
On a microscopic scale, conduction occurs within a body considered as being stationary; this means that the kinetic and potential energies of the bulk motion of the body are separately accounted for. [[First law of thermodynamics|Internal energy]] diffuses as rapidly moving or vibrating atoms and [[molecule]]s interact with neighboring particles, transferring some of their microscopic kinetic and potential energies, these quantities being defined relative to the bulk of the body considered as being stationary. Heat is transferred by conduction when adjacent atoms or molecules collide, or as several [[electrons]] move backwards and forwards from atom to atom in a disorganized way so as not to form a macroscopic electric current, or as phonons collide and scatter. Conduction is the most significant means of heat transfer within a solid or between solid objects in [[thermal contact]]. Conduction is greater in solids because the network of relatively close fixed spatial relationships between atoms helps to transfer energy between them by vibration.
 
Fluids (and especially gases) are less conductive. This is due to the large distance between atoms in a gas: fewer collisions between atoms means less conduction.  Conductivity of gases increases with temperature. Conductivity increases with increasing pressure from vacuum up to a critical point that the density of the gas is such that molecules of the gas may be expected to collide with each other before they transfer heat from one surface to another. After this point conductivity increases only slightly with increasing pressure and density.
 
[[Thermal contact conductance]] is the study of heat conduction between solid bodies in contact. A temperature drop is often observed at the interface between the two surfaces in contact. This phenomenon is said to be a result of a thermal contact resistance existing between the contacting surfaces. [[Interfacial thermal resistance]] is a measure of an interface's resistance to thermal flow. This thermal resistance differs from contact resistance, as it exists even at atomically perfect interfaces. Understanding the thermal resistance at the interface between two materials is of primary significance in the study of its thermal properties. Interfaces often contribute significantly to the observed properties of the materials.
 
The inter-molecular transfer of energy could be primarily by elastic impact as in fluids or by free electron diffusion as in metals or [[phonon|phonon vibration]] as in insulators. In [[thermal insulation|insulators]] the heat flux is carried almost entirely by [[phonon]] vibrations.
 
Metals (e.g. copper, platinum, gold,etc.) are usually good [[heat conduction|conductors]] of thermal energy.  This is due to the way that metals are chemically bonded:  [[metallic bond]]s (as opposed to [[covalent bonds|covalent]] or [[ionic bonds]]) have free-moving electrons which are able to transfer thermal energy rapidly through the metal.  The "electron fluid" of a [[Electrical conductor|conductive]] metallic solid conducts most of the heat flux through the solid. Phonon flux is still present, but carries less of the energy. Electrons also conduct [[electric current]] through conductive solids, and the [[thermal conductivity|thermal]] and [[electrical conductivity|electrical conductivities]] of most [[metal]]s have about the same ratio. A good electrical conductor, such as [[copper]], also conducts heat well.  [[Thermoelectricity]] is caused by the interaction of heat flux and electrical current.
Heat conduction within a solid is directly analogous to [[diffusion]] of particles within a fluid, in the situation where there are no fluid currents.
 
To quantify the ease with which a particular medium conducts, engineers employ the [[thermal conductivity]], also known as the conductivity constant  or conduction coefficient, ''k''.  In [[thermal conductivity]] ''k'' is defined as "the quantity of heat, Q, transmitted in time (t) through a thickness (L), in a direction normal to a surface of area (A), due to a temperature difference (ΔT) [...]."  Thermal conductivity is a material ''[[physical property|property]]'' that is primarily dependent on the medium's [[list of phases of matter|phase]], temperature, density, and molecular bonding.  [[Thermal effusivity]] is a quantity derived from conductivity which is a measure of its ability to exchange thermal energy with its surroundings.
 
===Steady-state conduction===
Steady state conduction is the form of conduction that happens when the temperature difference(s) driving the conduction are constant, so that (after an equilibration time), the spatial distribution of temperatures (temperature field) in the conducting object does not change any further. Thus, all partial derivatives of temperature ''with respect to space'' may either be zero or have nonzero values, but all derivatives of temperature at any point ''with respect to time'' are uniformly zero. In steady state conduction, the amount of heat entering any region of an object is equal to amount of heat coming out (if this were not so, the temperature would be rising or falling, as thermal energy was tapped or trapped in a region).
 
For example, a bar may be cold at one end and hot at the other, but after a state of steady state conduction is reached, the spatial gradient of temperatures along the bar does not change any further, as time proceeds. Instead, the temperature at any given section of the rod remains constant, and this temperature varies linearly in space, along the direction of heat transfer.
 
In steady state conduction, all the laws of direct current electrical conduction can be applied to "heat currents". In such cases, it is possible to take  "thermal resistances" as the analog to [[electrical resistance]]s. In such cases, temperature plays the role of voltage, and heat transferred per unit time (heat power) is the analog of electrical current. Steady state systems can be modelled by networks of such thermal resistances in series and in parallel, in exact analogy to electrical networks of resistors. See [[Lumped capacitance model#Thermal purely resistive circuits|purely resistive thermal circuits]] for an example of such a network.
 
===Transient conduction===
In general, during any period in which temperatures are changing ''in time'' at any place within an object, the mode of thermal energy flow is termed ''transient conduction.'' Another term is "non steady-state" conduction, referring to time-dependence of temperature fields in an object. Non-steady-state situations appear after an imposed change in temperature at a boundary of an object. They may also occur with temperature changes inside an object, as a result of a new source or sink of heat suddenly introduced within an object, causing temperatures near the source or sink to change in time.
 
When a new perturbation of temperature of this type happens, temperatures within the system will change in time toward a new equilibrium with the new conditions, provided that these do not change. After equilibrium, heat flow into the system will once again equal the heat flow out, and temperatures at each point inside the system no longer change. Once this happens, transient conduction is ended, although steady-state conduction may continue if there continues to be heat flow.
 
If changes in external temperatures or internal heat generation changes are too rapid for equilibrium of temperatures in space to take place, then the system never reaches a state of unchanging temperature distribution in time, and the system remains in a transient state.
 
An example of a new source of heat "turning on" within an object which causes transient conduction, is an engine starting in an automobile. In this case the transient thermal conduction phase for the entire machine would be over, and the steady state phase would appear, as soon as the engine had reached steady-state [[operating temperature]]. In this state of steady-state equilibrium, temperatures would vary greatly from the engine cylinders to other parts of the automobile, but at no point in space within the automobile would temperature be increasing or decreasing. After establishment of this state, the transient conduction phase of heat transfer would be over.
 
New external conditions also cause this process: for example the copper bar in the example steady-state conduction would experience transient conduction as soon as one end was subjected to a different temperature from the other. Over time, the field of temperatures inside the bar would reach a new steady-state, in which a constant temperature gradient along the bar will finally be set up, and this gradient would then stay constant in space. Typically, such a new steady state gradient is approached exponentially with time after a new temperature-or-heat source or sink, has been introduced. When a "transient conduction" phase is over, heat flow may still continue at high power, so long as temperatures do not change.
 
An example of transient conduction which does not end with steady-state conduction, but rather no conduction, occurs when a hot copper ball is dropped into oil at a low temperature. Here the temperature field within the object begins to change as a function of time, as the heat is removed from the metal, and the interest lies in analyzing this spatial change of temperature within the object over time, until all gradients disappear entirely (the ball has reached the same temperature as the oil). Mathematically, this condition is also approached exponentially; in theory it takes infinite time, but in practice it is over, for all intents and purposes, in a much shorter period. At the end of this process with no heat sink but the internal parts of the ball (which are finite), there is no steady state heat conduction to be reached. Such a state never occurs in this situation, but rather the end of the process is when there is no heat conduction at all.
 
Analysis of non steady-state conduction systems is more complex than steady-state systems, and (except for simple shapes) calls for the application of approximation theories, and/or numerical analysis by computer. One popular graphical method involves the use of [[Heisler Chart]]s.
 
Occasionally transient conduction problems may be considerably simplified if regions of the object being heated or cooled can be identified, in which [[thermal conductivity]] is very much greater than that for heat paths leading into the region. In this case, the region with high conductivity can often be treated in the [[lumped capacitance model]], as a "lump" of material with a simple thermal capacitance consisting of its aggregate [[heat capacity]]. Such regions show no temperature variation across their extent during warming or cooling (as compared to the rest of the system) due to their far higher conductance. During transient conduction, therefore, their temperature changes uniformly in space, and as a simple exponential in time. An example of such systems are those which follow "Newton's law of cooling" during transient cooling (or the reverse during heating). The equivalent thermal circuit consists of a simple capacitor in series with a resistor. In such cases, the remainder of the system with high thermal resistance (comparatively low conductivity) plays the role of the resistor in the circuit.
 
===Relativistic conduction===
The theory of [[relativistic heat conduction]] is a model that is compatible with the theory of special relativity.  For most of the last century, it was recognized that Fourier equation is in contradiction with the theory of relativity because it admits an infinite speed of propagation of heat signals. For example, according to Fourier equation, a pulse of heat at the origin would be felt at infinity instantaneously. The speed of information propagation is faster than the speed of light in vacuum, which is physically inadmissible within the framework of relativity. Alterations to the Fourier model provided for a relativistic model of heat conduction, avoiding this problem.
 
===Quantum conduction===
[[Second sound]] is a [[quantum mechanical]] phenomenon in which [[heat transfer]] occurs by [[wave equation|wave]]-like motion, rather than by the more usual mechanism of [[diffusion]]. Heat takes the place of pressure in normal sound waves. This leads to a very high [[thermal conductivity]].  It is known as "second sound" because the wave motion of heat is similar to the propagation of [[sound]] in air.
 
==Fourier's law==
The law of heat conduction, also known as [[Joseph Fourier|Fourier]]'s law, states that the time rate of [[heat transfer]] through a material is [[Proportionality (mathematics)|proportional]] to the negative [[gradient]] in the temperature and to the area, at right angles to that gradient, through which the heat is flowing. We can state this law in two equivalent forms: the integral form, in which we look at the amount of energy flowing into or out of a body as a whole, and the differential form, in which we look at the flow rates or [[Heat flux|fluxes]] of energy locally.
 
[[Newton's law of cooling]] is a discrete analog of Fourier's law, while [[Ohm's law]] is the electrical analogue of Fourier's law.
===Differential form===
The differential form of Fourier's Law of thermal conduction shows that the local [[heat flux]] density, <math>\overrightarrow{q}</math>, is equal to the product of [[thermal conductivity]], <math>k</math>, and the negative local temperature gradient, <math>-\nabla T</math>. The heat flux density is the amount of energy that flows through a unit area per unit time.
 
: <math>\overrightarrow{q}  = - k {\nabla} T</math>
 
where (including the [[SI]] units)
: <math>\overrightarrow{q}</math> is the local heat flux density, [[Watt|W]]·m<sup>−2</sup>
: <math>\big.k\big.</math> is the material's [[thermal conductivity|conductivity]], [[Watt|W]]·m<sup>−1</sup>·[[Kelvin|K]]<sup>−1</sup>,
: <math>\big.\nabla T\big.</math> is the temperature gradient, [[Kelvin|K]]·m<sup>−1</sup>.
The thermal conductivity, <math>k</math>, is often treated as a constant, though this is not always true. While the thermal conductivity of a material generally varies with temperature, the variation can be small over a significant range of temperatures for some common materials. In anisotropic materials, the thermal conductivity typically varies with orientation; in this case <math>k</math> is represented by a second-order [[tensor]]. In nonuniform materials, <math>k</math> varies with spatial location.
 
For many simple applications, Fourier's law is used in its one-dimensional form. In the x-direction,
 
: <math>q_x  = - k \frac{d T}{d x}</math>
 
===Integral form===
By integrating the differential form over the material's total surface <math>S</math>, we arrive at the integral form of Fourier's law:
 
: <math> \frac{\partial Q}{\partial t} = -k \oint_S{\overrightarrow{\nabla} T \cdot \,\overrightarrow{dA}} </math>
where (including the [[SI]] units):
* <math>\big. \frac{\partial Q}{\partial t}\big.</math> is the amount of heat transferred per unit time (in W), and
* <math>\overrightarrow{dA}</math> is an oriented surface area element (in m<sup>2</sup>)
<!-- Missing image removed: [[Image:exponential Heat flow.svg|thumb|200px|exponential heat flow]] -->The above [[differential equation]], when [[Integral|integrated]] for a homogeneous material of 1-D geometry between two endpoints at constant temperature, gives the heat flow rate as:
: <math> \big. \frac{\Delta Q}{\Delta t} = -k A \frac{\Delta T}{\Delta x} </math>
where
: ''A'' is the cross-sectional surface area,
: <math>\Delta T</math> is the temperature difference between the ends,
: <math>\Delta x</math> is the distance between the ends.
This law forms the basis for the derivation of the [[heat equation]].
 
==Conductance==
Writing
: <math>\big. U = \frac{k}{\Delta x}, \quad</math>
where ''U'' is the conductance, in W/(m<sup>2</sup> K).
 
Fourier's law can also be stated as:
 
: <math>\big. \frac{\Delta Q}{\Delta t} = U A\, (-\Delta T).</math>
 
The reciprocal of conductance is resistance, R, given by:
: <math> \big. R = \frac{1}{U} = \frac{\Delta x}{k} = \frac{A\, (-\Delta T)}{\frac{\Delta Q}{\Delta t}}, \quad</math>
 
and it is resistance which is additive when several conducting layers lie between the hot and cool regions, because ''A'' and ''Q'' are the same for all layers. In a multilayer partition, the total conductance is related to the conductance of its layers by:
 
: <math>\big. \frac{1}{U} = \frac{1}{U_1} + \frac{1}{U_2} + \frac{1}{U_3}+ \cdots</math>
 
So, when dealing with a multilayer partition, the following formula is usually used:
 
: <math>\big. \frac{\Delta Q}{\Delta t} = \frac{A\,(-\Delta T)}{\frac{\Delta x_1}{k_1} + \frac{\Delta x_2}{k_2} + \frac{\Delta x_3}{k_3}+ \cdots}.</math>
 
When heat is being conducted from one fluid to another through a barrier, it is sometimes important to consider the conductance of the [[thin film]] of fluid which remains stationary next to the barrier. This thin film of fluid is difficult to quantify, its characteristics depending upon complex conditions of [[turbulence]] and [[viscosity]], but when dealing with thin high-conductance barriers it can sometimes be quite significant.
 
===Intensive-property representation===
The previous conductance equations, written in terms of [[Intensive and extensive properties|extensive properties]], can be reformulated in terms of [[Intensive and extensive properties|intensive properties]].
 
<!-- material was posted as a revision suggestion for the article  -->
Ideally, the formulae for conductance should produce a quantity with dimensions independent of distance, like [[Ohm's Law]] for electrical resistance: <math>R = V/I\,\!</math>, and conductance: <math> G = I/V \,\!</math>.
 
From the electrical formula: <math>R = \rho x / A \,\!</math>, where ρ is resistivity, x is length, and A is cross-sectional area, we have <math>G = k A / x \,\!</math>, where G is conductance, k is conductivity, x is length, and A is cross-sectional area.
 
For Heat,
 
: <math>\big.  U = \frac{k A} {\Delta x}, \quad</math>
where ''U'' is the conductance.
 
Fourier's law can also be stated as:
 
: <math>\big. \dot{hhQ} = U \, \Delta T \quad</math>
 
analogous to Ohm's law: <math> I = V/R \,\!</math> or <math> I = V G. \,\!</math>
 
The reciprocal of conductance is resistance, R, given by:
: <math>\big. R = \frac{\, \Delta T}{\dot{Q}}, \quad</math>
 
analogous to Ohm's law: <math> R = V/I. \,\!</math>
 
The rules for combining resistances and conductances (in series and in parallel) are the same for both heat flow and electric current.
 
===Cylindrical shells===
Conduction through cylindrical shells (e.g. pipes) can be calculated from the internal radius, <math>r_1</math>, the external radius, <math>r_2</math>, the length, <math>\ell</math>, and the temperature difference between the inner and outer wall, <math>T_2 - T_1</math>.
 
The surface area of the cylinder is <math>A_r= 2 \pi r \ell</math>
 
When Fourier’s equation is applied:
 
:<math>\dot{Q} = -k A_r \frac{\mathrm{d}T}{\mathrm{d}r} = -2 k \pi r \ell \frac{\mathrm{d}T}{\mathrm{d}r}</math>
 
and rearranged:
 
:<math>\dot{Q} \int_{r_1}^{r_2} \frac{1}{r} \mathrm{d}r = -2 k \pi \ell \int_{T_1}^{T_2} \mathrm{d}T</math>
 
then the rate of heat transfer is:
 
:<math>\dot{Q} = 2 k \pi \ell \frac{T_1 - T_2}{\ln (r_2 /r_1)}</math>
 
the thermal resistance is:
 
:<math>R_c = \frac{\Delta T}{\dot{Q}}= \frac{\ln (r_2 /r_1)}{2 \pi k \ell}</math>
 
and <math>\dot{Q} = 2 \pi k \ell r_m \frac{T_1-T_2}{r_2-r_1}</math>, where <math>r_m = \frac{r_2-r_1}{\ln (r_2 /r_1)}</math>. It is important to note that this is the log-mean radius.
 
===Spherical===
The conduction through a spherical shell with internal radius, <math>r_1</math>, and external radius, <math>r_2</math>, can be calculated in a similar manner as for a cylindrical shell.
 
The [[surface area]] of the sphere is: <math>\!A = 4\pi r^2.</math>
 
Solving in a similar manner as for a cylindrical shell (see above) produces:
<math>\dot{Q} = 4 k \pi \frac{T_1 - T_2}{1/{r_1}-1/{r_2}} = 4 k \pi \frac{(T_1 - T_2) r_1 r_2}{r_2-r_1}</math>
 
==Transient Thermal Conduction==
 
===Interface Heat Transfer===
{{Citation needed|date=May 2013}}
The heat transfer at an interface is considered a transient heat flow. To analyze this problem, the Biot number is important to understand how the system will behave. The Biot number is determined by:
<math> Bi= \frac{hL}{k} </math>
The heat transfer coefficient, h, is introduced in this formula, and is measured in <math> \frac{J}{m^{2}sK} </math>.
If the system has a Biot number of less than 0.1, the material behaves according to Newtonian cooling, i.e. with negligible temperature gradient within the body. If the Biot number is greater than 0.1, the system will behave as a series solution. The temperature profile in terms of time can be determined by the function can be derived from the equation:
 
<math>q=-h \Delta T </math>
 
Which will become:
 
<math> \frac{T-T_{f}}{T_{i} - T_{f}} = \operatorname{exp} \left [ \frac{-hAt}{\rho C_p V} \right ] </math>
 
The [[heat transfer coefficient]], h, is measured in <math> \frac{W}{m^{2}K} </math>, and represents the transfer of heat at an interface between two materials. This value is different at every interface, and is an important concept in understanding heat flow at an interface.
 
The Series Solution can be analyzed with a [[nomogram]]. A nomogram has relative temperature as the y coordinate and the Fourier number, which is calculated by:
<math>Fo= \frac{\alpha t}{L^2} </math>
The Biot number increases as the Fourier number decreases. There are 5 steps to determine a temperature profile in terms of time.
# Calculate the Biot number
# Determine which relative depth matters, either x or L.
# Convert time to the Fourier number.
# Convert <math>T_i</math> to relative temperature with the boundary conditions.
# Compared required point to trace specified Biot number on the nomogram.
 
==Thermal Conduction Applications==
 
===Splat Cooling===
 
[[Splat cooling]] is a method for quenching small droplets of molten materials by rapid contact with a cold surface. The particles undergo a characteristic cooling process, with the heat profile at <math>t=0</math> for initial temperature as the maximum at <math>x=0</math> and <math>T = 0</math> at <math>x = -\infin</math> and <math> x = \infin </math>, and the heat profile at <math>t=\infin </math> for <math>-\infin \le x  \le \infin</math> as the boundary conditions. Splat cooling rapidly ends in a steady state temperature, and is similar in form to the Gaussian diffusion equation. The temperature profile, with respect to the position and time of this type of cooling, varies with:
 
<math> T(x,t) - T_i = \frac{T_i \Delta X}{2\sqrt{\pi \alpha t}} \operatorname{exp} \left ( -\frac{x^2}{4 \alpha t} \right ) </math>
 
Splat cooling is a fundamental concept that has been adapted for practical use in the form of [[thermal spraying]]. The [[thermal diffusivity coefficient]], represented as alpha, can be written as <math> \alpha =\frac{k}{\rho C_p} </math>. This varies according to the material.<ref name="ZhangZhao2012">{{cite book|author1=Sam Zhang|author2=Dongliang Zhao|title=Aeronautical and Aerospace Materials Handbook|url=http://books.google.com/books?id=PJQmI7hix8kC&pg=PA304|accessdate=7 May 2013|date=19 November 2012|publisher=CRC Press|isbn=978-1-4398-7329-8|pages=304–}}</ref><ref name="Eein2002">{{cite book|author=Martin Eein|title=Drop-Surface Interactions.|url=http://books.google.com/books?id=qecltbmIbC4C&pg=PA174|accessdate=7 May 2013|year=2002|publisher=Springer|isbn=978-3-211-83692-7|pages=174–}}</ref>
 
===Metal Quenching===
 
Metal [[quenching]] is a transient heat transfer process in terms of the [[Time Temperature Transformation]] (TTT). It is possible to manipulate the cooling process to adjust the phase of a suitable material. For example, appropriate quenching of steel can convert a desirable proportion of its content of [[austenite]] to [[martensite]], creating a very tough product. To achieve this it is necessary to quench at the “nose” of the TTT diagram. Since materials differ in their [[Biot number]]s, the time it takes for the material to quench, or the [[Fourier number]], will vary in practice.<ref name="AsthanaKumar2006">{{cite book|author1=Rajiv Asthana|author2=Ashok Kumar|author3=Narendra B. Dahotre|title=Materials Processing and Manufacturing Science|url=http://books.google.com/books?id=oWRXvrgFhqUC&pg=PA158|accessdate=7 May 2013|date=9 January 2006|publisher=Butterworth-Heinemann|isbn=978-0-08-046488-6|pages=158–}}</ref> In steel, the quenching temperature range is generally from 600°C to 200°C. To control the quenching time and to select suitable quenching media, it is necessary to determine the Fourier number from the desired quenching time, the relative temperature drop, and the relevant Biot number. Usually the correct figures are read from a standard [[nomogram]].{{Citation needed|date=May 2013|reason=Where is this nomogram published?}}  By calculating the heat transfer coefficient from this Biot number, we can find a liquid medium suitable for the application.<ref name="Totten2002">{{cite book|author=George E. Totten|title=Handbook of Residual Stress and Deformation of Steel|url=http://books.google.com/books?id=_a9UEHk4cOwC&pg=PA322|accessdate=7 May 2013|year=2002|publisher=ASM International|isbn=978-1-61503-227-3|pages=322–}}</ref>
 
==Zeroth law of thermodynamics==
 
One statement of the so-called [[zeroth law of thermodynamics]] is directly focused on the idea of conduction of heat. Bailyn (1994) writes that "... the zeroth law may be stated:
 
::All diathermal walls are equivalent."<ref>Bailyn, M. (1994). ''A Survey of Thermodynamics'', American Institute of Physics, New York, ISBN 0-88318-797-3, page 23.</ref>
 
A [[Thermodynamic system#Boundary|diathermal wall]] is a connection of contiguity between two bodies that allows the passage of heat by conduction between them.
 
This statement of the 'zeroth law' belongs to an idealized theoretical discourse, and actual physical walls do not match such generality.
 
But with suitable restrictions, the statement has physical import. For example, the material of the wall must not undergo a phase transition, such as evaporation or fusion, at the temperature at which it has to conduct heat. But when only thermal equilibrium is being considered, and time is not urgent, so that the conductivity of the material does not matter too much, one suitable conductor of heat is as good as another. Conversely, another aspect of the zeroth law is that, subject again to suitable restrictions, a given diathermal wall is indifferent to the nature of the heat bath to which it is connected. For example the glass bulb of a thermometer will act as a diathermal wall whether exposed to a gas or to a liquid, provided they do not corrode it or melt it.
 
These indifferences are amongst the defining characteristics of [[heat transfer]]. In a sense they are [[Symmetry (physics)|symmetries]] of heat transfer.
 
==See also==
* [[List of thermal conductivities]]
* [[Electrical conduction]]
* [[Convection diffusion equation]]
* [[R-value|R-value (insulation)]]
* [[Heat pipe]]
* [[Fick's law of diffusion]]
* [[Relativistic heat conduction]]
* [[Thermomass theory]]
* [[Churchill-Bernstein Equation]]
* [[Fourier number]]
* [[Biot number]]
* [[False diffusion]]
 
==References==
{{Reflist}}
 
*Dehghani, F 2007, CHNG2801 – Conservation and Transport Processes: Course Notes, University of Sydney, Sydney
* John H Lienhard IV and John H Lienhard V, 'A Heat Transfer Textbook', Third Edition, Phlogyston Press, Cambridge Massachusetts [http://web.mit.edu/lienhard/www/ahtt.html]
 
==External links==
* [https://www.thermalfluidscentral.org/e-encyclopedia/index.php/Heat_conduction Heat conduction] - Thermal-FluidsPedia
* [http://demonstrations.wolfram.com/NewtonsLawOfCooling/ Newton's Law of Cooling] by Jeff Bryant based on a program by [[Stephen Wolfram]], [[Wolfram Demonstrations Project]].
*[http://www.WhenWillMyTurkeyBeDone.com When Will My Turkey Be Done?] is an example of applied heat conduction equations similar to Newton's Law of Cooling which predict the cooking time of turkeys and other roasts.
 
{{DEFAULTSORT:Thermal Conduction}}
[[Category:Concepts in physics]]
[[Category:Heat conduction]]
[[Category:Physical quantities]]
[[Category:Heat transfer]]
 
[[af:Warmtegeleiding]]
[[be:Цеплаправоднасць]]
[[be-x-old:Цеплаправоднасьць]]
[[bg:Топлопроводимост]]
[[et:Soojusjuhtivus]]
[[io:Termala kondukto]]
[[kk:Жылу өткізгіштік]]
[[ht:Kondiksyon]]
[[lv:Siltumvadītspēja]]
[[lt:Šiluminis laidumas]]
[[ml:താപചാലകം]]
[[ta:வெப்ப கடத்தல்]]
[[th:การนำความร้อน]]
[[tr:Kondüksiyon]]

Revision as of 20:23, 6 February 2014

My name is Ashly Yamamoto. I life in Hamburg Hausbruch (Germany).

Also visit my page; Fifa 15 Coin Generator [blog.infidels.co.za]